email [email protected] +86-18865798103

Get a Free Quote

Our representative will contact you soon.
Email
Message
0/1000
Mobile/WhatsApp
Name
Company Name
r290 side discharge inverter-0

Heat Pump

Home >  Products >  Heat Pump

ALL PRODUCTS

R290 SIDE DISCHARGE INVERTER

Side Discharge Design: Optimizes air circulation efficiency, suitable for installations with limited surrounding space;

Eco-Friendly R290 Refrigerant: Meets high environmental standards while maintaining efficient heat transfer;

Wide Adaptability: Supports multi-voltage configurations (208/230V) and a broad ambient temperature range (-15-43℃);

Durable Build: Titanium alloy heat exchangers and IPX4/IPX7 protection enhance longevity in pool-side humid environments.

  • Introduction
  • Main features
  • Specifications
  • Recommended
Product Introduction
The Demax Side Discharge Inverter R290 is a frequency-conversion swimming pool heat pump featuring a side-discharge air outlet design. It adopts R290 (propane) refrigerant (highly eco-friendly with ultra-low GWP) and is engineered to adapt to both residential and small commercial swimming pools, covering a wide range of pool volumes for flexible application.

Core Configuration & Key Details:

Refrigerant: R290 (propane) — eco-friendly with minimal global warming impact;
Design & Components: Side-discharge air outlet structure; equipped with electronic expansion valves, titanium alloy/PVC heat exchangers (corrosion-resistant for pool water environments);
Protection & Durability: Protection level up to IPX7 (for partial models), ensuring reliability in outdoor/humid pool settings;
Operating Range: Adapts to an ambient temperature range of -15-43℃, with a maximum outlet water temperature of 42℃, suitable for diverse climate conditions.

R290 SIDE DISCHARGE INVERTER1.jpg
Main features

Performance Specifications:

This product includes multiple JDLKRY-series models, with core performance parameters as follows:
Recommended Pool Volume: Covers 12-25 m³ to 58-115 m³ (accommodating small home pools to medium commercial pools);
Heating Capacity: Under standard conditions (Air 27℃/Water 26℃), heating power ranges from 2.78 kW to 12.3-45 kW (corresponding to 9200-42778 BTU/h); the maximum Standard Heating COP reaches 5.78, delivering high energy efficiency;
Cooling Capacity: Under rated conditions (Air 35℃/Water 30℃), cooling power ranges from 3.982 kW to 16.04 kW (corresponding to 1296-54774 BTU/h);
Noise Level: Operates at 45-57 dBA, balancing performance with quiet operation.

Core Features:

Side Discharge Design: Optimizes air circulation efficiency, suitable for installations with limited surrounding space;
Eco-Friendly R290 Refrigerant: Meets high environmental standards while maintaining efficient heat transfer;
Wide Adaptability: Supports multi-voltage configurations (208/230V) and a broad ambient temperature range (-15-43℃);
Durable Build: Titanium alloy heat exchangers and IPX4/IPX7 protection enhance longevity in pool-side humid environments.

R290 SIDE DISCHARGE INVERTER2.jpg
Specifications

Application Scenarios:

Ideal for small residential swimming pools, medium-sized commercial pools (e.g., villa pools, small club pools), and scenarios requiring both pool temperature control and stable operation in low-temperature environments.

R290 SIDE DISCHARGE INVERTER
Model JDLKRY-5FE1 JDLKRY-8FE1 JDLKRY-10FE1 JDLKRY-12FE1 JDLKRY-15FE1 JDLKRY-18FE1 JDLKRY-24FE1 JDLKRY-24FE2
Recommended Pool Volume M3 12-25 19-38 24-50 28-56 36-70 43-90 58-115 58-115
Power supply V/Ph/HZ 208-230V/1/
50HZ/60HZ
208-230V/1/
50HZ/6OHZ
208-230V/1/
50HZ/60HZ
208-230V/1
50HZ/60HZ
208-230V/1/
50HZ/60HZ
208-230V/1/
50HZ/60HZ
208-230V/1/
50HZ/60HZ
208-230V/1/
50HZ/60HZ
Refrigerant R290
Operating Environment Temperature -15-43
Max.Outlet Water Temperature 42
Min.Outlet Water Temperature 8
Heating Capacity KW 2.7-8 4.4-12.9 4.7-14.5 6.2-18.5 6.6-20.9 8.3-24.5 12.6-34.5 12.6-34.5
BTU 9200-27288 15000-44000 16031-49459 21148-63100 22512-71289 28311-83569 42978-117679 42978-117679
Standard Heating Condition (Air 27°℃/Water 26°C/Humid.80%)
Standard Heating Capacity KW 6.75 10.8 13.3 16.1 20.2 24.1 32.2 32.3
BTU 23024 36839 45366 54917 68902 82205 109834 110175
Standard Heating Power KW 1.17 1.89 2.32 2.82 3.56 4.19 5.63 5.63
Standard Heating Current A 5.13 8.3 10.2 12.38 15.63 18.4 24.74 9.5*3
COP W/W 5.75 5.71 5.74 5.71 5.68 5.75 5.72 5.74
Rated Heating Condition (Air 15/Water 26°C/Humid.70.8%)
Rated Heating Capacity KW 5 8 9.8 11.9 14.9 17.8 23.8 23.8
BTU 17055 27288 33428 40591 50824 60716 81182 81182
Rated Heating Power KW 1.11 1.8 2.2 2.64 3.3 3.97 5.28 5.28
Rated Heating Current A 4.87 7.9 9.66 11.6 14.5 17.43 23.2 8.91*3
COP W/W 4.5 4.43 4.45 4.5 4.48 4.48 4.51 4.51
Rated Cooling Condition (Air 35°℃/Water 30°C/Humid.40.3%)
Rated Cooling Capacity 42638 56964 56964 KW 3.8 6 6.86 8.3 10.4 12.5 16.7 16.7
BTU 12962 20466 23399 28311 35474 42638 56964 56964
Rated Cooling Power KW 1.19 1.9 2.8 2.44 3.04 4.55 5.96 5.96
Rated Cooling Current 5.23 A 5.23 8.3 9.1 10.72 13.40 19.97 26.20 10*3
EEP W/W 3.2 3.15 3.3 3.4 3.42 2.75 2.8 2.8
Max.Current 7.9 9.7 12.3 15.4 19.8 19.8 26.4 10.1*3
Water pipe connection MM 50/48.3 50/48.3 50/48.3 50/48.3 50/48.3 50/48.3 50/48.3 50/48.3
Water Flow M3 2.14 3.42 4.2 5.1 6.38 7.63 10.2 10.2
Water Side Pressure Resistance KPA 4 5 7 9 11 12 13 13
Protection Level IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4
Motor CD
Throtle Device Electronic
Expansion Valve
Electronic
Expansion Valve
Electronic
Expansion Valve
Electronic
Expansion Valve
Electronic
Expansion Valve
Electronic
Expansion Valve
Electronic
Expansion Valve
Electronic
Expansion Valve
Heat Exchanger PVC Titanium Alloy Heat Exchanger
Noise (dBA) 45 47 48 50 53 56 57 57

R290 SIDE DISCHARGE INVERTER3.jpgR290 SIDE DISCHARGE INVERTER4.jpg

Get a Free Quote

Our representative will contact you soon.
Email
Message
0/1000
Mobile/WhatsApp
Name
Company Name

Get a Free Quote

Our representative will contact you soon.
Email
Message
0/1000
Mobile/WhatsApp
Name
Company Name