Single Phase Hybrid Inverter -EPL Series(3-10kW)
EPL series 3kw to 10kw solar hybrid inverter is an ideal solution for solar energy storage, it boasts of top industrial level asymmetric three phase output, accurate power export limit and extremely low self power consumption. With clear display view from the LCD screen, easy remote settings, easy graphics operations on app and web, communications by WIFI, P2P, LAN, GPRS, RS485.
- Introduction
- Main features
- Specifications
- Recommended
Product Introduction
EPL series 3kw to 10kw solar hybrid inverter is an ideal solution for solar energy storage, it boasts of top industrial level asymmetric three phase output, accurate power export limit and extremely low self power consumption. With clear display view from the LCD screen, easy remote settings, easy graphics operations on app and web, communications by WIFI, P2P, LAN, GPRS, RS485.
EPL series 3kw to 10kw solar hybrid inverter is an ideal solution for solar energy storage, it boasts of top industrial level asymmetric three phase output, accurate power export limit and extremely low self power consumption. With clear display view from the LCD screen, easy remote settings, easy graphics operations on app and web, communications by WIFI, P2P, LAN, GPRS, RS485.
![]() |
Load consumption monitoring | ![]() |
Big LCD display |
![]() |
Power export limit | ![]() |
IP65 protection |
Main features
Smart Control Monitoring:
Users can check 24-hour load consumption enabled Demax monitoring solution . And built-in anti-back flow limit is available to control export power.
![]() |
24hours loads consumption monitoring |
![]() |
Power export limit |

Specifications
| Single Phase Hybrid Inverter-EPL Series(3-10kW) | ||||||
| Model No | EPL3000TL | EPL4000TL | EPL5000TL | EPL6000TL | EPL8000TL | EPL10KTL |
| Input(DC) | ||||||
| Max DC Power (W) | 4500W | 6000W | 7500W | 9000W | 12000W | 14000W |
| Max DC Voltage (Vdc) | 500 | |||||
| Rated PV Input Voltage | 360V(100~500V) | |||||
| MPPT Voltage range (Vdc) | 100~450 | |||||
| Max Input current (A) | 18A/18A | 27A/27A | ||||
| Max Input short circuit per MPPT | 25A/25A | 50A/50A | ||||
| Number of MPP trackers | 2 | 2 | ||||
| Strings per MPP tracker | 1 | 2 | ||||
| BATTERY INPUT | ||||||
| Battery Type | Lead-acid or Li-ion | |||||
| Battery voltage range(V) | 40-60V | |||||
| Max. charge current(A) | 80 | 100 | 120 | 150 | 200 | 210 |
| Max. discharge current(A) | 80 | 100 | 120 | 150 | 200 | 210 |
| Exernal temperature sensor | Yes | |||||
| Charging Curve | 3 Stages/Equalization | |||||
| Charging stratege for Li-ion Battery | Self-adaption to BMS | |||||
| Output(AC) | ||||||
| Rated AC output Active power (W) | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 |
| Maximum AC output Active power (W) | 3300 | 4400 | 5500 | 6600 | 8800 | 10500 |
| AC output Rated Current (A) | 13.1 | 17.4 | 21.8 | 26.2 | 34.8 | 43.5 |
| Max.AC output Current (A) | 15 | 20 | 24.2 | 28.8 | 38.5 | 45.6 |
| Max. Continuous AC Passthrough (A) | 35A | 65A | ||||
| Peak Power(off grid) | 2 time of rated power, 10s | |||||
| Power factor adjustment range | 0.8 leading to 0.8 lagging | |||||
| Power factor | 1 | |||||
| Output Frequency and voltage | 50/60Hz;L/N/PE 220/230Vac | |||||
| Grid type | Single phase | |||||
| Total Harmonic Distortion(THD) | <0.5%In | |||||
| Efficiency | ||||||
| Maximum conversion efficiency | 97.6% | 97.6% | 97.6% | 97.8% | 97.8% | 97.8% |
| European efficiency | 96.5% | 96.5% | 96.5% | 96.6% | 96.6% | 96.6% |
| MPPT efficiency | 99.9% | 99.9% | 99.9% | 99.9% | 99.9% | 99.9% |
| Safety and Protection | ||||||
| Interrated | Anti-islanding protection, PV String input Reverse Polarity Protection Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection Output Shorted Protection, Surge Protection |
|||||
| Over Voltage Category | DC Type II/AC Type III | |||||
| General Parameters | ||||||
| Dimension(W/H/D)(mm) | 520*420*180 | |||||
| Weight(kg) | 25 | |||||
| Protection degree | IP65 according to IEC60529 | |||||
| Operation temperature (°C) | -40 ~ +60,>45°C Derating | |||||
| Cooling concept | Smart Cooling | |||||
| Acoustic noise level (dB) | <30 | |||||
| Installation Style | Wall-mounted | |||||
| Communication with BMS | RS485;CAN | |||||
| Warranty | Standard 5 years; 7/10 years optional | |||||
| Certificates and Approvals | ||||||
| CQC,VDE-AR-N4105,IEC61727,IEC62116,VDE0124-AR-N0124,EN50549,IEC62109.IEC62477 | ||||||